USERS AREA:
|
Battery Discharger and Tester 160A
- The system can perform capacity tests by discharging 2 to 96V batteries (up to 800Ah) in 5h max.
- Battery voltage and discharge current are easily programmable through dedicated select switches.
- All functions can be programmed in the local mode by means of a keyboard with display.
- A PC can be connected to store data concerning charge and discharge cycles.
Operation:
- Programming of battery rated voltage and discharge current.
- Possible reprogramming of number of charge and discharge cycles (3), minimum voltage (1.7 V/cell), and discharge time (5h).
- Connection to battery, battery charger, and mains.
- Test start through a START/STOP button.
- On test completion the local display will show:
- Battery efficiency (%)
- Minimum voltage reached (V/cell)
- Discharge time (h:mm)
- On test completion following data can be displayed and printed through a PC:
- Pages containing main data
- Voltage and current diagrams
|
AUTOMATIC MANAGEMENT OF CHARGE/DISCHARGE CYCLES
|
Technical features
- Linear operation
- Battery voltage range: 4V to 96V
- Discharge current: 0A to 160A
- Power supply: 230V AC / 500A
- Room temperature: –10 to +50°C
- Overall dimensions: 400x400x880 mm
- Weight: 49 Kg
- Equipped with a blue Anderson battery connector (SBE-320)
- Equipped with a grey Anderson battery charger connector (SBE-320)
- Storage of main charge and discharge data (up 200 cycles)
|
|